Procedure - 7.3

Processing (Integration)

Version
7.3
Language
English
Product
Talend Big Data
Talend Big Data Platform
Talend Data Fabric
Talend Data Integration
Talend Data Management Platform
Talend Data Services Platform
Talend ESB
Talend MDM Platform
Talend Real-Time Big Data Platform
Module
Talend Studio
Content
Data Governance > Third-party systems > Processing components (Integration)
Data Quality and Preparation > Third-party systems > Processing components (Integration)
Design and Development > Third-party systems > Processing components (Integration)
Last publication date
2024-02-21

Procedure

  1. Drop the following components required for this use case: tFixedFlowInput, tSplitRow and tLogRow from the Palette to the design workspace.
  2. Connect them together using Row Main connections.
  3. Double-click tFixedFlowInput to open its Basic settings view.
  4. Select Use Inline Content(delimited file) in the Mode area.
  5. Fill the Content area with the following scripts:
    Talend;LA;California;537;5thAvenue;IT;Lionbridge;Memphis;Tennessee;537;Lincoln Road;IT Service;
  6. Click Edit schema to open a dialog box to edit the schema for the input data.
  7. Click the plus button to add twelve lines for the input columns: Company, City, State, CountryCode, Street, Industry, Company2, City2, State2, CountryCode2, Street2 and Industry2.
  8. Click OK to close the dialog box.
  9. Double-click tSplitRow to open its Basic settings view.
  10. Click Edit schema to set the schema for the output data.
  11. Click the plus button beneath the tSplitRow_1(Output) table to add four lines for the output columns: Company, CountryCode, Address and Industry.
  12. Click OK to close the dialog box. Then an empty table with column names defined in the preceding step will appear in the Columns mapping area:
  13. Click the plus button beneath the empty table in the Columns mapping area to add two lines for the output rows.
  14. Fill the table in the Columns mapping area by columns with the following values:
    Company: row1.Company, row1.Company2;
    Country: row1.CountryCode, row1.CountryCode2;
    Address: row1.Street+","+row1.City+","+row1.State, row1.Street2+","+row1.City2+","+row1.State2;
    Industry: row1.Industry, row1.Industry2;
    Note:

    The value in Address column, for example, row1.Street+","+row1.City+","+row1.State, will display an absolute address by combining values in Street column, City column and State column together. The "row1" used in the values of each column refers to the input row from tFixedFlowInput.

  15. Double-click tLogRow to open its Basic settings view.
  16. Click Sync columns to retrieve the schema defined in the preceding component.
  17. Select Table in the Mode area.
  18. Save the Job and press F6 to run it.

Results

The input data in one row is split into two rows of data containing the same company information.