- Double-click the tLoop component to display its Basic settings view.
- Select For as the loop type. Type in 1, 2 1 in the From, To and Step fields respectively. Keep the Values are increasing check box selected.
-
Double-click the tFixedFlowInput
component to display its Basic settings
view.
-
Select Built-In from the Schema drop-down list.
Tip: You can select Repository in the Schema drop-down list to fill in the relevant fields automatically if the relevant metadata has been stored in the Repository. For more information about Metadata, see Managing metadata in Studio.
-
Click Edit schema to define the data
structure of the input flow. In this case, the input has one column:
Name.
- Click OK to close the dialog box.
- Fill in the Number of rows field to specify the entries to output, for example 1.
- Select the Use Single Table check box. In the Values table, assign a value to the Name field, e.g. Marx.
-
Double-click tHashOutput to display
its Basic settings view.
- Select Built-In from the Schema drop-down list and click Sync columns to retrieve the schema from the previous component; select Keep all from the Keys management drop-down list and deselect the Append check box.