Understanding the Talend JobServer clean-up cycle - 7.0

Talend Data Integration Installation Guide for Windows

EnrichVersion
7.0
EnrichProdName
Talend Data Integration
task
Installation and Upgrade
EnrichPlatform
Talend Activity Monitoring Console
Talend Administration Center
Talend Artifact Repository
Talend CommandLine
Talend Data Preparation
Talend Data Stewardship
Talend Identity and Access Management
Talend Installer
Talend JobServer
Talend Log Server
Talend Runtime
Talend Studio

The Talend JobServer cleans up Job artifacts on a schedule, based on data cleaning parameters. You can customize the Talend JobServer clean-up schedule by changing the parameters in TalendJobserver.properties file, listed under Temporary data cleaning parameters. Configuring these values is optional.

General clean-up frequency

The general clean-up schedule is defined by the FREQUENCY_CLEAN_ACTION parameter. You can disable the general clean-up by setting this parameter to 0.

Job repository, archive, and execution clean-up

Job artifacts are cleaned up in the next clean-up cycle when the following conditions are met:

  • The Job is not running.
  • The Job execution is released. Note that when you stop the server all Jobs are released.
    • The Job is released after 50 Job executions. The frequency is determined by MIN_NUMBER_JOB_EXECUTIONS_BEFORE_RELEASE parameter.
    • A Job execution is released after 5 minutes under normal circumstances and after 24 hours under abnormal circumstances. These times are defined by the MAX_DURATION_BEFORE_JOB_EXECUTION_RELEASE_NORMAL_CASE and MAX_DURATION_BEFORE_JOB_EXECUTION_RELEASE_ABNORMAL_CASE parameters.
    • After a Job is released, the cleaning action for Jobs and archives occurs when the MAX_DURATION_BEFORE_CLEANING_OLD_JOBS and MAX_OLD_JOBS parameters are met. You can change the parameters values in the properties file.
    • After a Job is released, the cleaning action for logs occurs when the MAX_DURATION_BEFORE_CLEANING_OLD_EXECUTION_LOGS or MAX_OLD_EXECUTION_LOGS parameters are met. You can change the parameters values in the properties file.
      Note: For each MAX_OLD_* and MAX_DURATION_* parameter pair, whichever is reached first will trigger a cleaning action.