TPS-4167 (cumulative patch) - 7.0

author
Talend Documentation Team
EnrichVersion
7.0
EnrichProdName
Talend Data Fabric
Talend MDM Platform
EnrichPlatform
Talend MDM Server
Talend MDM Web UI
Talend Studio

TPS-4167 (cumulative patch)

Info Value
Patch Name Patch_20200909_TPS-4167_v1
Release Date 2020-09-09
Target Version 20180411_1414-7.0.1
Product affected Talend MDM Server, Talend Studio

Introduction

This patch is cumulative. It includes all previous generally available patches for MDM 7.0.1

NOTE: For information on how to obtain this patch, reach out to your Support contact at Talend.

Fixed issues

This patch contains the following fixes:

  • TPS-2734 [7.0.1] Issue with date field defined as a primary key (TMDM-12624)
  • TPS-2893 [7.0.1] Talend MDM timeout cannot be increased with IAM enabled (TMDM-12908)
  • TPS-3657 [7.0.1] MDM ignores OIDC client claimIssueAtExpiration property (TMDM-14344)
  • TPS-3931 [7.0.1] Bulk update issue when SSL is configured (TMDM-12040)
  • TPS-4167 [7.0.1] Deploy Data Model fails after Element removed : ORA-00904: "X_VERSION" : invalid identifier (TMDM-14709)
  • TMDM-12028 Deleting a foreign key causes MDM to raise an exception - POC!!
  • TMDM-12346 Remove field existing in view failed (MSSQL)
  • TMDM-12515 Can't prepare DB if field's type is MULTI_LINGUAL or boolean and has default value
  • TMDM-12038 [Impact Analysis] High change when move a simple field from mandatory to optional in an complex type
  • TMDM-12215 Deploy DM failed when move a complex mandatory field (containing a simple optional field) to optional
  • TMDM-14722 Deploy datamodel fails after remove element from inheritance type
  • TMDM-14795 Deleting a foreign key causes MDM to raise an exception (Oracle DB)
  • TMDM-14709 Deploy Data Model fails after Element removed : ORA-00904: "X_VERSION" : invalid identifier

Prerequisites

Consider the following requirements for your system:

  • Talend Studio 7.0.1 must be installed.
  • Talend MDM Server 7.0.1 must be installed.

Installation

PATCH INSTALLATION NOTES FOR TALEND MDM SERVER 7.0.x

PRE-INSTALLATION

  • Stop the MDM server
  • Create a patch directory (eg: C:\MDM_Patch)
  • Unzip patch file you receive from support into this directory
  • Create a backup directory (eg: C:\MDM_Backup)

WEB APPLICATION REPLACEMENT

  • Copy folder <MDM_SERVER_HOME>/apache-tomcat/webapps/talendmdm into the backup directory
  • Replace it with the folder talendmdm contained in patch directory

POST-INSTALLATION

  • Restart the MDM server
  • Clear browser cache on clients