Skip to main content Skip to complementary content

Setting up the Job

Procedure

  1. Drop the following components from the Palette onto the design workspace: tFixedFlowInput, tDataQualityRules, tExtractJSONFields, tFilterRow and three tLogRow components.
  2. Using Main links, connect:
    • tFixedFlowInput to tDataQualityRules
    • tDataQualityRules to one tLogRow
    • tExtractJSONFields to tFilterRow
  3. Using Filter links, connect tFilterRow to another tLogRow.
  4. Using Reject links, connect:
    • tDataQualityRules to tExtractJSONFields
    • tFilterRow to the last tLogRow
    Information noteTip: If you want valid data only, connect tDataQualityRules to only one tLogRow component using a Main link. You do not need the tExtractJSONFields and tFilterRow components.