DD_for_OpenEdge registry key

The DD_for_OpenEdge key is available if Talend Change Data Capture for OpenEdge Source module is installed (see Installing Progress OpenEdge source).

For each instance followed by Talend Change Data Capture, you will get a subkey.

This subkey will have the instance name.

Parameter Description

AttemptComWait

Time period before attempting a reconnection between source engine and target engine. This time period can be repeated.

Default value is 30 seconds.

ddSchedulerWait

Period of time before the Scheduler program relaunches the planning tasks or the tasks that were executed but are not finished yet.

Default value is 30 seconds.

DriverName

This parameter contains the ODBC driver name used to access the OpenEdge database. The default value is the OpenEdge Driver value found on the machine.

For example, for a version x of OpenEdge, the driver name would probably be Progress OpenEdge 10.2B Driver.

PathSource

This parameter contains the path where the programs are installed.

It is recommended not to modify this parameter.

SpvWait

This parameter contains the time in seconds between two executions of the Supervisor module (see OpenEdge). The default value is 30 seconds.

WaitBeforeKill

Delay in milliseconds between the sending of the stop command (when stopping is a voluntary action) and the sending of the terminate command.

Default value is 1000 ms.

For more information on how to use this parameter, contact Talend Support team.